{"id":1859,"date":"2023-09-21T18:51:05","date_gmt":"2023-09-21T18:51:05","guid":{"rendered":"https:\/\/ivd.carrottechlab.net\/the-development-of-condensate-during-compression-2\/"},"modified":"2023-09-26T07:33:46","modified_gmt":"2023-09-26T07:33:46","slug":"the-development-of-condensate-during-compression-2","status":"publish","type":"page","link":"https:\/\/ivd.carrottechlab.net\/en\/the-development-of-condensate-during-compression-2\/","title":{"rendered":"THE DEVELOPMENT OF CONDENSATE DURING COMPRESSION"},"content":{"rendered":"<div class=\"wl\">\n\t<article data-theme=\"light\">\n\t\t<h3>\n\t\t\tCALCULATION STEP 1: AMOUNT OF WATER SUCKED INTO THE COMPRESSOR\t\t<\/h3>\n\t\t<div class=\"wl-calculator\">\n\t\t\t<div class=\"wl-formula\">\n\t\t\t\t<img src=\"https:\/\/ivd.carrottechlab.net\/wp-content\/plugins\/wl-formulas-shortcodes\/assets\/img\/calculation_condensate_1.gif\" alt=\"Formula 1 - Calculation of the failing condensate for compressors\" title=\"Formula 1 - Calculation of the failing condensate for compressors\"\/>\n\t\t\t<\/div>\n\t\t\t<div class=\"row\">\n\t\t\t\t<div class=\"col-lg-6\">\n\t\t\t\t\t<label for=\"air_temperature_on_suction_side\">\n\t\t\t\t\t\tAir temperature on suction side [\u00b0C] <br>\n\t\t\t\t\t\t(Temperature at installation site)\t\t\t\t\t\t<input type=\"text\" id=\"air_temperature_on_suction_side\" name=\"air_temperature_on_suction_side\" placeholder=\"Air temperature on suction side\" required>\n\t\t\t\t\t<\/label>\n\t\t\t\t\t<label for=\"relative_humidity_of_the_intake_air\">\n\t\t\t\t\t\tRelative humidity of the intake air \u03c6<sub>1<\/sub> [%]\t\t\t\t\t\t<input type=\"text\" id=\"relative_humidity_of_the_intake_air\" name=\"relative_humidity_of_the_intake_air\" placeholder=\"Relative humidity of the intake air\" required>\n\t\t\t\t\t<\/label>\n\t\t\t\t\t<label for=\"compressor_delivery_quantity\">\n\t\t\t\t\t\tCompressor delivery quantity V<sub>1<\/sub>3\/min]\t\t\t\t\t\t<input type=\"text\" id=\"compressor_delivery_quantity\" name=\"compressor_delivery_quantity\" placeholder=\"Compressor delivery quantity\" required>\n\t\t\t\t\t<\/label>\n\t\t\t\t\t<label for=\"final_compression_pressure\">\n\t\t\t\t\t\tFinal compression pressure P<sub>e<\/sub>[bar\u00fc]\t\t\t\t\t\t<input type=\"text\" id=\"final_compression_pressure\" name=\"final_compression_pressure\" placeholder=\"Final compression pressure\" required>\n\t\t\t\t\t<\/label>\n\t\t\t\t\t<button id=\"wl-calculate\" class=\"site-button\">Calculate<\/button>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"col-lg-6\">\n\t\t\t\t\t<div id=\"wl-resultbox\" class=\"wl-bg-success\">\n\t\t\t\t\t\t<p>Amount of water sucked into<br>the compressor (m <sub>Water In<\/sub>) <\/p>\n\t\t\t\t\t\t<div class=\"wl-result\">\n\t\t\t\t\t\t\t<span id=\"wl-result\">0,00<\/span> [l\/h]\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/div>\n\t\t<br><br><br><br>\n\t\t<h3>\n\t\t\tCALCULATION STEP 2: CONDENSATE ACCUMULATION AFTER THE COMPRESSOR\t\t<\/h3>\n\t\t<div class=\"wl-calculator\">\n\t\t\t<div class=\"wl-formula\">\n\t\t\t\t<img src=\"https:\/\/ivd.carrottechlab.net\/wp-content\/plugins\/wl-formulas-shortcodes\/assets\/img\/calculation_condensate_2.gif\" alt=\"Formula 2 - Calculation of the failing condensate for compressors\" title=\"Formula 1 - Calculation of the failing condensate for compressors\"\/>\n\t\t\t<\/div>\n\t\t\t<div class=\"row\">\n\t\t\t\t<div class=\"col-lg-6\">\n\t\t\t\t\t<label for=\"outlet_temperature_compressed_air_after\">\n\t\t\t\t\t\tOutlet temperature of the compressed air after<br> the aftercooler of the compressor T<sub>2<\/sub> [\u00b0C]\t\t\t\t\t\t<input type=\"text\" id=\"outlet_temperature_compressed_air_after\" name=\"outlet_temperature_compressed_air_after\" placeholder=\"Outlet temperature of the compressed air\" required>\n\t\t\t\t\t<\/label>\n\t\t\t\t\t<button id=\"wl-calculate-2\" class=\"site-button\">Calculate<\/button>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"col-lg-6\">\n\t\t\t\t\t<div id=\"wl-resultbox-2\" class=\"wl-bg-success\">\n\t\t\t\t\t\t<p>Condensate failure n.d. compressor <\/p>\n\t\t\t\t\t\t<div class=\"wl-result\">\n\t\t\t\t\t\t\t<span id=\"wl-result-21\">0,00<\/span> [l\/h]\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<p>Remaining residual moisture i. i.e. compressed air <\/p>\n\t\t\t\t\t\t<div class=\"wl-result\">\n\t\t\t\t\t\t\t<span id=\"wl-result-22\">0,00<\/span> [l\/h]\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/div>\n\t\t<br><br><br><br>\n\t\t<h3>\n\t\t\tCALCULATION STEP 3: CONDENSATE ACCUMULATION AFTER THE REFRIGERATION DRYER\t\t<\/h3>\n\t\t<div class=\"wl-calculator\">\n\t\t\t<div class=\"wl-formula\">\n\t\t\t\t<img src=\"https:\/\/ivd.carrottechlab.net\/wp-content\/plugins\/wl-formulas-shortcodes\/assets\/img\/calculation_condensate_3.gif\" alt=\"Formula 2 - Calculation of the failing condensate for compressors\" title=\"Formula 1 - Calculation of the failing condensate for compressors\"\/>\n\t\t\t<\/div>\n\t\t\t<div class=\"row\">\n\t\t\t\t<div class=\"col-lg-6\">\n\t\t\t\t\t<label for=\"pressure_dew_point_of_the_refrigeration_dryer\">\n\t\t\t\t\t\tPressure dew point of the refrigeration dryer T<sub>3<\/sub> [\u00b0C]\t\t\t\t\t\t<input type=\"text\" id=\"pressure_dew_point_of_the_refrigeration_dryer\" name=\"pressure_dew_point_of_the_refrigeration_dryer\" placeholder=\"Pressure dew point of the refrigeration dryer\" required>\n\t\t\t\t\t<\/label>\n\t\t\t\t\t<button id=\"wl-calculate-3\" class=\"site-button\">Calculate<\/button>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"col-lg-6\">\n\t\t\t\t\t<div id=\"wl-resultbox-3\" class=\"wl-bg-success\">\n\t\t\t\t\t\t<p>Condensate failure n.d. refrigeration dryer <\/p>\n\t\t\t\t\t\t<div class=\"wl-result\">\n\t\t\t\t\t\t\t<span id=\"wl-result-31\">0,00<\/span> [l\/h]\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<p>Remaining residual moisture i. i.e. compressed air <\/p>\n\t\t\t\t\t\t<div class=\"wl-result\">\n\t\t\t\t\t\t\t<span id=\"wl-result-32\">0,00<\/span> [l\/h]\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/div>\n\t\t<br><br><br><br>\n\t\t<h3>\n\t\t\tCALCULATION STEP 4: TOTAL CONDENSATE\t\t<\/h3>\n\t\t<div class=\"wl-calculator\">\n\t\t\t<div class=\"wl-formula\">\n\t\t\t\t<img src=\"https:\/\/ivd.carrottechlab.net\/wp-content\/plugins\/wl-formulas-shortcodes\/assets\/img\/calculation_condensate_4.gif\" alt=\"Formula 2 - Calculation of the failing condensate for compressors\" title=\"Formula 1 - Calculation of the failing condensate for compressors\"\/>\n\t\t\t<\/div>\n\t\t\t<div class=\"row\">\n\t\t\t\t<div class=\"col-lg-12\">\n\t\t\t\t\t<div id=\"wl-resultbox-4\" class=\"wl-bg-success\">\n\t\t\t\t\t\t<p>Total condensate discharged <\/p>\n\t\t\t\t\t\t<div class=\"wl-result\">\n\t\t\t\t\t\t\t<span id=\"wl-result-4\">0,00<\/span> [l\/h]\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t<p><strong>Remarks<\/strong><\/p>\n\t\t\t<ol>\n\t\t\t\t<li>Air 100% saturated after compression<\/li>\n\t\t\t\t<li>Pressure at installation site 1.01325 bar (atmospheric pressure)<\/li>\n\t\t\t\t<li>The maximum humidity of the temperature at the installation site fmax TU [g\/m\u00b3] is taken from a stored table<\/li>\n\t\t\t\t<li>The maximum humidity of the temperature after the compressor outlet fmax TA [g\/m\u00b3] is taken from a stored table<\/li>\n\t\t\t\t<li>The maximum humidity of the temperature after the refrigeration dryer fmax T3 [g\/m\u00b3] is taken from a stored table<\/li>\n\t\t\t<\/ol>\n\t\t<\/div>\n\t\t<div class=\"row wl-calculator-info\">\n\t\t\t<div class=\"col-lg-2 center-xs\">\n\t\t\t\t<span class=\"dashicons dashicons-info-outline\"><\/span>\n\t\t\t<\/div>\n\t\t\t<div class=\"col-lg-10\">\n\t\t\t\t<p>\n\t\t\t\t\t<strong>Did you know<\/strong>  that in a day shift (8h full load):\n\t\t\t\t<\/p>\n<!--\t\t\t\t<p>&nbsp;<\/p>-->\n\t\t\t\t<ul class=\"wl-list-normal\">\n\t\t\t\t\t<li>at a volume flow of 1000 m\u00b3\/h,<\/li>\n\t\t\t\t\t<li>a final compression pressure of 10 bar (g) and<\/li>\n\t\t\t\t\t<li>a humidity of 60% (at 30\u00b0C) a total of approx. <strong>140 l condensate<\/strong> is produced?<\/li>\n\t\t\t\t<\/ul>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/article>\n<\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/ivd.carrottechlab.net\/en\/wp-json\/wp\/v2\/pages\/1859"}],"collection":[{"href":"https:\/\/ivd.carrottechlab.net\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ivd.carrottechlab.net\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ivd.carrottechlab.net\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/ivd.carrottechlab.net\/en\/wp-json\/wp\/v2\/comments?post=1859"}],"version-history":[{"count":1,"href":"https:\/\/ivd.carrottechlab.net\/en\/wp-json\/wp\/v2\/pages\/1859\/revisions"}],"predecessor-version":[{"id":1860,"href":"https:\/\/ivd.carrottechlab.net\/en\/wp-json\/wp\/v2\/pages\/1859\/revisions\/1860"}],"wp:attachment":[{"href":"https:\/\/ivd.carrottechlab.net\/en\/wp-json\/wp\/v2\/media?parent=1859"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}